Below you'll find the wiring instructions for many of our automatic tools, if you do not see your tool listed or have questions please feel free to contact us at 1-888-438-6324 or via email at info@stanmech.com.

For all machines: Screw down the wire contacts on to the bare electrical wire only and do not clamp down on the insulation of the wire. Bad contacts cause sparking which may cause the cord to heat up and may damage equipment.

Jump to a tool:
ASTRO
COMET
BITUMAT
FUSION
UNIFLOOR
UNIMAT
UNIPLAN
UNIROOF
VARIANT T1
VARIMAT
WELDMAX
WELDPLAST


ASTRO

Please consider the following when connecting a new plug to your ASTRO:

  • Specifications of the plug: 15 Amp; 250 Volt; 2 pole; 3 wire; grounding; twist-lock
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab

Please consider the following when making an extension cord for your ASTRO:

  • Use a 12 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the ASTRO
  • Shut-down procedure:
    1. Switch off the ASTRO
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


COMET

Please consider the following when connecting a new plug to your COMET:

  • Specifications of the plug: 15 Amp; 250 Volt; 2 pole; 3 wire; grounding; twist-lock

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab

Please consider the following when making an extension cord for your COMET:

  • Use a 12 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the COMET
  • Shut-down procedure:
    1. Switch off the COMET
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


BITUMAT

Please consider the following when connecting a new plug to your BITUMAT:

  • You must use 30 Amp or higher twist-lock plug
  • The BITUMAT is single phase
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your BITUMAT:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the BITUMAT
  • Shut-down procedure:
    1. Switch off the BITUMAT
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


FUSION Wiring Instructions

Connecting a twist-lock plug to your FUSION:

  • Specifications of the plug: 20 Amp; 250 Volt; 2 pole; 2 wire; non-grounding; twist-lock
  • Connect one wire to either one of the plug pins
  • Connect the other wire to the other pin

Please consider the following when making an extension cord for your FUSION:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the FUSION
  • Shut-down procedure:
    1. Switch off the FUSION
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


UNIFLOOR Wiring Instructions

Plug specifications: 125V; 15A; 2-pole; grounded; male

Connecting a plug:

  • Connect the green wire to the ground pin
  • Connect the white wire to either remaining pin
  • Connect the black wire to the last pin

Please consider the following when making an extension cord for your UNIFLOOR:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the UNIFLOOR
  • Shut-down procedure:
    1. Switch off the UNIFLOOR
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


UNIMAT Wiring Instructions

Please consider the following when connecting a plug to your UNIMAT:

  • You must use a 20 Amp or higher twist-lock plug
  • The UNIMAT is single phase
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your UNIMAT:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


UNIPLAN Wiring Instructions

Connecting a plug:

  • Connect the green wire to the ground pin
  • Connect the white wire to either remaining pin
  • Connect the black wire to the last pin

Please consider the following when making an extension cord for your UNIPLAN:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


UNIROOF Wiring Instructions

Please consider the following when connecting a plug to your UNIROOF:

  • You must use a 20 Amp or higher twist-lock plug
  • The UNIROOF is single phase
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your UNIROOF:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


VARIANT T1

Please consider the following when connecting a new plug to your VARIANT T1:

  • You must use 20 Amp or higher twist-lock plug
  • The VARIANT T1 is single phase
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your VARIANT T1:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the VARIANT T1
  • Shut-down procedure:
    1. Switch off the VARIANT T1
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


VARIMAT Wiring Instructions

Please consider the following when connecting a new plug to your VARIMAT:

  • You must use 30 Amp or higher twist-lock plug
  • The VARIMAT is single phase
  • When using a generator make sure the plug is wired for A/C

Connecting a twist-lock plug:

  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your VARIMAT:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the VARIMAT
  • Shut-down procedure:
    1. Switch off the VARIMAT
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


WELDMAX Wiring Instructions

Connecting a 120 V plug to your WELDMAX:

  • You must use a 15 Amp or higher plug
  • Connect the white wire to the silver connector
  • Connect the black wire to the bronze connector
  • Do not connect any wires to the ground pin of the plug

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com

Jump to top


WELDPLAST Wiring Instructions

Connecting a plug to your WELDPLAST:

  • Specifications of the plug:
    • For WELDPLAST S2, S2 PVC, S4: 20 Amp or higher; 250 Volt; 2 pole; 3 wire; grounding; twist-lock
    • For WELDPLAST S6: 30 Amp or higher; 250 Volt; 2 pole; 3 wire; grounding; twist-lock
  • Connect the green wire to the pin with the bent tab
  • Connect the white wire to one of the pins directly left or right of the bent tab
  • Connect the black wire to the other pin directly left or right of the bent tab
  • If using a 4 prong plug, leave the red wire and the pin opposite the one with the bent tab disconnected

Please consider the following when making an extension cord for your WELDPLAST:

  • Use a 10 Gauge or thicker cable if you plan to make a 100 ft or longer extension cord
  • If you wish to use a 4 wire cable, leave the red wire and the pin opposite the one with the bent tab disconnected

Generator Instructions:

  • Starting procedure:
    1. Switch on the generator
    2. Switch on the WELDPLAST
  • Shut-down procedure:
    1. Switch off the WELDPLAST
    2. Switch off the generator

Still have questions? Give us a call at 1-888-438-6324 or email info@stanmech.com