FOT_FUSION_2_dvD3856.jpg

  • The FUSION is not producing the correct heat
    • Confirm that the correct element has been installed.  The elements for the FUSION 2 and 3C are not the same as the element for the FUSION 3.
    • Check that the air intake filter (located on the housing in front of the extrusion trigger) is clean. A plugged filter will reduce air flow and heat transfer and could cause the element to burn out. Remove any blockage in the filter with a soft brush.

  • Use the correct plug and wire, as detailed in the wiring instructions.